Calibrator

Jofra CTC1200A temperature calibrator


High accuracy at high temperatures

CTC-1200A has a unique design, his built-in standard sensor is placed in a special perforated casing and a nonlinear heating element. In combination with the MVI function, it is possible to achieve high accuracy and stability without the need for an external sensor when the sensor is calibrated with different sizes. CTC-1200A can provide 110mm insertion depth, calibrate the sensor below 12mm diameter, while it has a smaller size to carry.

CTC series industrial dry calibration instrument

Jofra CTC series industrial dry temperature calibrator is very suitable for use in the field, the calibration process is fast, reliable, and has MVI function and supporting software. Portability and calibration speed are significantly better than the liquid tank, and do not use the liquid, while a wider temperature range. CTC dry temperature calibrator can calibrate thermal resistance, thermocouple, temperature switch, and other general purpose temperature sensors.

Maximum temperature protection function

CTC series can be set to the maximum temperature limit, used to protect the sensor was calibrated to avoid damage due to over application temperature. At the same time, the sensor's drift caused by high temperature is avoided. This feature can also be locked through a password.

Intuitive simple operation

Intuitive simple operation, Jofra CTC-1200A temperature calibrator

All functions can be operated directly on the panel, heating area design position and operation panel separation, so as to protect the operator. The main function of CTC is a key corresponding to a function, no complicated menus. LCD display clear and easy to read, and there is an icon to indicate the current state.

Operation and setting

Fast through the up and down arrow keys to set the temperature of 0.1 DEG C. In addition, the resolution can also set the unit stability standard, display resolution, contrast, slope (heating rate), automatic step set and maximum temperature setting.

Stability indicator

When the calibration instrument reaches the set temperature and number of a bold will remain stable on the screen after the sign. The operator can change the stability conditions to achieve more stringent calibration results. 5 minutes before the calibration to achieve stability, there will be a countdown sign to achieve a stable time.

Automatic switch test

Automatic switch test, Jofra CTC-1200A temperature calibrator

The use of automatic switching test function to record the temperature of the temperature of the opening and closing of the switch can save calibration time. And can also display the dead value between two points. Just press the switch test key can be automatic switch test.

Automatic stepping

Up to 9 steps can be set up automatically, including the stability of each step. This feature allows the CTC to be placed on the site to automatically control the temperature, the operator can observe the sensor data in the control room.

Recalibration and adjustment

The new CTC calibration method is very simple, no software or screwdriver, only need a standard reference thermometer. The reference thermometer is inserted into the instrument, in accordance with the instructions on the screen can be re calibrated. A lot of Metrology departments or calibration laboratories can do this work, and can issue calibration certificate.

Liquid filled sensor (pressure thermometer) or temperature switch

CTC-320B and CTC-650B have a higher 190mm insertion depth and can be calibrated with a liquid filled thermometer. CTC-650B has a specially designed nonlinear heating element and a larger size of the casing, so that the whole heating temperature is highly consistent. This allows the entire length of the sensor parts are placed at the same temperature, resulting in high calibration accuracy and repeatability.

Calibration software

All CTC with RS232 interface and AMECAL-LIGHT software. This software is a WINDOWS application software, you can set different calibration procedures, simple and intuitive operation. This software can print calibration reports in accordance with ISO-9000 specifications. AMETEK-LIGHT software support all RS232 interface with the JOFRA body calibration instrument including JOFRA DTI1000 high precision thermometer. In semi-automatic calibration applications, the software can also support the liquid trough, such as freezing point.

Standard configuration

CTC-140A/320/650/1200 standard configuration

CTC dry temperature calibrator (user specified model)

Power cord

Traceability Certificate - temperature performance

Casing (user specified)

Casing tool

RS232 communication cable

JofraCal application software

User manual (multiple languages, including Chinese)

Reference manual (English)

Test line

CTC series has the following models:

CTC-140A, CTC-320A, CTC-320B

CTC-650A, CTC-650B, CTC-1200A

双语对照